With its extensive technical and engineering expertise and a state of the art compound facility general cable is committed to using materials with the best overall properties to create the most comprehensive line of industrial power cables to meet your design requirements.
Medium voltage cable shield grounding.
Shield losses shield grounding and shield terminations are also discussed.
That of carrying a portion of return ground fault current.
Shielding of electric power cable results in symmetric electric field distribution within the cable insulation and prevents stress damage.
The most overlooked if not a well understood factor is the type of power cable that s required for the application and when to ground the cable s neutral or tape shield.
Verification of shield performance under ground fault conditions will prevent systemwide cable damage as we all know the metallic shielding in a medium voltage mv cable provides the necessary uniform electric field within the cable s insulation.
From an engineering standpoint there are several factors one needs to consider before installing the cable.
Installing medium voltage power cables underground comes with its own set of challenges.
It is noted that in essence the conductor shield is an electrical extension of.
What is not as well known is its other equally important function.
General cable is recognized as a world class leader in the development and design of medium voltage industrial cables.
Medium and high voltage power cables in circuits over 2000 volts usually have a shield layer of copper or aluminum tape or conducting polymer.
If an unshielded insulated cable is in contact with earth or a grounded object the electrostatic field around the conductor will be concentrated at the contact point resulting in corona discharge.
Medium high voltage cable types of the nearly limitless variety of cables in use today five of the most common are.
Tape shielded drain wire shielded general cable unishield concentric neutral cn jacketed concentric neutral jcn beyond cable shield types two common configurations are used.
Grounding methods and requirements for systems operating at more than 1 000 volts v such as 5 and 15 kilovolt kv systems differ slightly from those for systems of 1 000v or less.
Medium voltage cable shielding and grounding abstract.
This article discusses the medium voltage mv or high voltage hv cable shield grounding or termination methods.
The authors describe the purposes of the shields conductor shield insulation shield and metal shield in medium voltage cables.
Single conductor.